Integrates the ControlArt 7Port Mini IR/RF/RTS gateway with Control4, with native access to its 3 IR outputs and relay to control any device that has a Control4 IR driver.
This driver only works with the 7Port Mini hardware. With another model it reports it in Driver Information and does not send commands.
Companion drivers in the package, linked to the gateway through the xBus Gateway connection:
ZoomDH – ControlArt IR/RF Relay: IR and RF 433 relays, with the standard Control4 proxies (gate, fireplace, motors).
ZoomDH – ControlArt IR/RF Device: general purpose IR and RF 433 commands.
ZoomDH – ControlArt Blind: curtains and blinds with IR, RF 433 and RTS motors (Somfy and Tube).
Requirements
ControlArt 7Port Mini gateway with a fixed IP on the controller network.
IP set with 7Config.
Control4 OS 2.9.1 or later, with internet access for the license.
Installation
Set the 7Port Mini IP with 7Config.
Add the ZoomDH – ControlArt 7Port Mini driver to the project.
Enter the IP in IP Address. The driver checks the model and shows the serial number and firmware.
Enter the key in License Key (the driver has a 30-day trial).
Bind IR Output 1 to 3 and Relay 1 in the Connections tab.
For RF 433 and RTS, add the companion drivers and pair the RTS motors with the Adicionar motor RTS action (or import the IDs stored by 7Config).
Properties
Property
Description
License Key
Driver license key. Without a key the driver runs in 30-day trial mode.
License Status
License state (trial, active or invalid).
Control4 MAC Address
Controller MAC, used to register the license.
Driver Name / Driver Version
Installed driver name and version.
Log Level / Log Mode
Log detail and destination (Lua tab).
Driver Information
Last driver message (device found, command sent, errors).
Hardware Model
Fixed to 7Port Mini.
IP Address
Gateway IP. The driver discovers the model, TCP port, serial and firmware over the network (UDP 4040) and then opens the TCP connection.
TCP Port
TCP port read from the device (default 4998). Read only.
Device Serial Number / Device FW Version
Serial number and firmware read from the device.
Connection Status
Connection state with the gateway.
RF Command Interval Milliseconds
Delay between one RF 433/RTS command and the next. Default: 1200.
IR Command Interval Milliseconds
Delay between one IR command and the next. Default: 300.
Actions
Action
Description
Adicionar motor RTS (Add RTS motor)
Creates an RTS remote (Somfy or Tube) and pairs it with the motor. Enter the name and type, put the motor in programming mode (press the motor button or an already paired remote until it makes a short move) and click OK. The motor makes another short move to confirm.
Alterar o nome do motor RTS (Rename RTS motor)
Renames an RTS remote in the list.
Excluir link RTS (Remove RTS link)
Unlinks an RTS remote from the blind driver.
Importar IDs RTS do 7Port/xPort (Import RTS IDs)
Reads the RTS remotes stored in the device (for example, created with 7Config/xConfig).
Limpar e recarregar RTS do 7Port/xPort (Clear and reload RTS)
Clears the driver RTS list and imports it again from the device.
Listar motores RTS (List RTS motors)
Prints the driver RTS list in the Lua tab.
Connections
ID
Connection
Use
1 to 3
IR Output 1 to 3
IR outputs.
901
Relay 1
7Port Mini relay.
100
7Port Mini
Link to the companion drivers (IR/RF Relay, IR/RF Device and Blind).
Troubleshooting
"Hardware não é 7Port Mini": the IP belongs to another model. Use the ZoomDH – ControlArt 7Port IP or xPort Pro driver.
Driver does not find the device: check the IP in IP Address and that the device answers on the network (same network as the controller, UDP 4040 allowed).
Connection Status off-line: the driver reconnects on its own. Check cable and power, and that another software (7Config/xConfig) is not holding the connection.
IR command does not work: check the IR output bound to the device in the Connections tab and the emitter position. Increase IR Command Interval Milliseconds for long macros.
RTS motor does not pair: the motor must be in programming mode and within range of the gateway when you click OK.
License: see License Status and Driver Information.
Licensing
Without a key the driver runs in 30-day trial mode. To activate it, enter the key in License Key.
The controller needs internet access to validate the license. The license is checked periodically.
Without a valid license the driver does not send commands to the device.
Customers who already have a license for this line keep the same key when updating.
Once a day, also during the trial, the driver reports technical data of the installation to the license server (controller model and version, driver version, project name and license state). No personal data is sent. When a new driver version is available, it shows in License Status with the link to the driver page on the website.
The driver now reports the installation's technical data to the license server once a day, which speeds up support. It also shows in License Status when a new driver version is available.