Driver that integrates the Home Manager automation system with Crestron Home through the Smart Center controller on the network (TCP, port 18080). It is the same driver ZOOM offers for Control4, adapted to Crestron Home: instead of one driver per device, the Smart Center driver reads the list of configured devices and creates each one in Crestron Home by itself, for the integrator to place in a room.
user/ThirdPartyDrivers/Import (SFTP, port 22, Crestron Home administrator user).| Field | Description |
|---|---|
| Smart Center IP Address | Smart Center IP (required). |
| TCP Port | Smart Center TCP port. Default 18080. |
| UI Language / Idioma | Portuguese or English: language of the driver screens. |
| Command Delay (ms) | Interval between commands sent to the Smart Center (100 to 1000 ms, default 250). |
| Air Conditioner Modes | Cool: air conditioners only cool. Cool,Heat: heat mode is offered too. |
| Air Conditioner Min / Max Setpoint (C) | Temperature range offered for the air conditioners (default 18 to 30 °C). |
| No Motion Delay (s) | Time without motion before the No Motion Timeout event of the motion sensors (default 30 s). |
| Click Delay (ms) | Input modules: time to count clicks; a press longer than this is a Hold (default 600 ms). |
| License Key | ZOOM license key. Empty: 30-day trial. |
The driver sends a keep alive every 60 seconds and reconnects by itself if the connection drops or the Smart Center stops answering.
On connection, the driver asks for the device list and the status of every device. Each Home Manager ID becomes a Crestron Home device, with the name set on the Smart Center. The list is saved on the processor, so the devices stay in the project even if the Smart Center is off when the processor restarts.
| Home Manager type | In Crestron Home |
|---|---|
| LD, LDR (relay) | On/off light. |
| DIM (dimmer) | Light with level, in 5% steps as in Home Manager. |
| RGB, RGBI | Light with level and a selector of the 13 Home Manager colors. |
| PER, PIR (shade/blind) | Shade with position (5% steps), open, stop and close. |
| GAT, GTR, GTS (gate/trigger) | Trigger button that sends a pulse. |
| ARZ, HVAC (air conditioner) | Thermostat with power, mode and temperature. |
| TMT (floor heating) | Thermostat with power, setpoint and room temperature. |
| TMP, LGT, MOV, OPN | Temperature, light, motion or contact sensor. |
| BIO (door lock) | Lock, unlock, last access and battery (warning below 30%). |
| KPD (inputs) | Up to 16 inputs, with the last action of each and events for sequences. |
| SCE (scene) | Not a device: listed in the scene selector of the driver page and in the Run Home Manager Scene command. |
Infrared (IRZ, IRF) and audio/video (MMZ) modules have no Crestron Home equivalent and are not created; the Devices line shows how many are not supported.
When a device is renamed in Home Manager, its name changes in Crestron Home. When the Smart Center reports a device as offline, it shows offline until its next status.
| Device | Commands | Events |
|---|---|---|
| Smart Center (driver) | Reconnect, Refresh Device List, Query Devices Status, Check License, Run Home Manager Scene. | - |
| Light | On, Off, Toggle, Set Level, Set Level With Fade, Set Color, Set Color (RRGGBB). | - |
| Shade | Open, Close, Stop, Toggle, Set Position. | - |
| Gate/trigger | Trigger. | Active, Inactive. |
| Air conditioner / floor heating | Power On, Power Off, Toggle Power, Set Mode, Set Setpoint, Setpoint Up, Setpoint Down, Send Command. | Turned On, Turned Off. |
| Sensors | - | Motion Detected, Motion Stopped, No Motion Timeout; Opened, Closed; Light Level Changed; Temperature Changed. |
| Door lock | Lock, Unlock, Toggle. | Locked, Unlocked, Alarm, Battery Low. |
| Inputs | - | For each input: Press, Release, Click, Double Click, Hold (with the input name). |
| Symptom | Likely cause / fix |
|---|---|
| "Offline, retrying in 5 s" | Check IP and port (18080), that IP integration is enabled on the Smart Center and that the processor reaches it on the network. |
| "Incompatible software version" | Update the Smart Center to HM 72 or later. Until then the driver sends no commands. |
| A device does not show up | Use Refresh list. Infrared and audio/video types are not supported. |
| A removed device is still listed | Use Refresh list (removes the IDs the Smart Center no longer lists). |
| Device offline | The Smart Center reported a communication error with the module. Check the module in Home Manager. |
| Input clicks counted wrong | Adjust Click Delay. |
| "Connected - commands blocked (license)" | Trial expired or invalid license: enter or check the key in License Key. |
| An updated driver changes nothing | The processor only replaces the driver when the version changes. Always use a package with a new version. |
The driver log (err command on the processor SSH console) shows connections, errors and warnings in Portuguese.
The driver runs for 30 days as a trial. After that, a license key must be entered in License Key. Without a valid license, the driver stays connected but sends no commands and does not update the device state, as in the Control4 driver. Licenses can be per processor or per driver instance.
| Version | Date | Description |
|---|---|---|
| 2026111101 | 2026-11-11 | The driver now reports the installation's technical data to the license server once a day, which speeds up support. It also shows in License Status when a new driver version is available. |
| 2026102602 | 2026-10-26 | First Crestron Home release: every device set up on the Smart Center shows up in Crestron Home with its Home Manager name (lights, dimmers, RGB, shades, gates, air conditioners, floor heating, sensors, door lock and inputs), with icons that follow the state. Scenes from the driver page and from sequences. The device list is kept on the processor. ZOOM license. |