Version 2 of the Absolute Controls integration. A single driver talks to the Absolute Smarthub gateway over the local network and hands each module channel to the ZOOM universal drivers, the same ones used with Lutron, Home Manager IP and other systems:
Absolute and Roehn keypads and QuickLight buttons: ZOOM – Universal Keypad Bus.
Push-buttons on the PNET inputs: ZOOM – Universal Keypad Dry Contact.
Thermostats: ZOOM – Universal HVAC Indoor Unit.
The gateway finds the modules on the ACNET network by itself and creates the universal drivers already connected. You can also register each module by hand. The license lives only on the gateway.
Prerequisites
Absolute Smarthub gateway on the local network, with a fixed or reserved IP.
Absolute modules already addressed on the ACNET network (Module ID of each one) and the ID of each thermostat.
ZOOM universal drivers installed on the Composer computer: Universal Light, Universal Blind, Universal Keypad, Universal Keypad Dry Contact and Universal HVAC Indoor Unit (free, on the ZOOM website).
Control4 OS 3.0 or later. RGB strip color from OS 3.3.
Controller with internet access for the license.
Installation
Add the ZOOM – Absolute Controls Gateway driver to the project in Composer Pro.
Enter the Smarthub IP in IP Address and check Connection Status.
Enter the key in License Key (30-day trial).
With Discovery Mode = Automatic (default), the gateway asks the Smarthub for the state of everything when it connects and registers the modules and thermostats that answer. Check the result in Registered Devices and with the Show Devices action.
Fix or complete what is needed with Add Module (model, Module ID and name) and Add Thermostat (Thermostat ID and, if there is one, the Thermopad ID, temperature sensor). Manual registration always prevails over automatic.
With Auto Create Devices = Yes, the gateway creates the universal drivers in its own room, already connected. Then just move each one to its room and rename it if you want.
With Auto Create Devices = No, add the universal drivers by hand and connect each one to the gateway connection with the same name (Connections tab). The Create Missing Devices action creates only the ones that do not exist yet.
Automatic discovery
On connection (and with the Discover Modules action), the gateway asks for the state of every module. Each Module ID that answers is registered with the model deduced from the channels it reports.
Shades: ADP-LX4. Outputs with LEDs: QuickLight. LEDs only: keypad (KP-1, KP-3, KP-6 or Roehn 8, by its buttons). Outputs only: GreenPlug (more than 12), ADP-RL12 (9 to 12), ADP-DIM8 (5 to 8) and, up to 4, AQL-GV-PMW3/PMW4 or AQL-GV-RL4.
If an automatically registered module later shows more channels, it moves to the larger model, keeping the connections already made.
Some models have the same number of channels (for example AQL-GV-PMW4, AQL-GV-010V4 and AQL-GV-RL4, or PMW3 and RGB, or KP-6 and Roehn 4). Check and, if needed, use Add Module with the right model: the outputs that remain keep their connections.
Thermostats join when they report mode, fan or setpoint. The Thermopad ID is entered by hand, in Add Thermostat.
With Discovery Mode = Manual, nothing is registered by itself: the Module IDs seen on the network are listed in Unregistered Modules.
Models and what each one creates
Model (Add Module)
Connections created
ADP-DIM8
8 dimmable outputs. Push-buttons on the 6 PNET inputs.
ADP-RL12
12 on/off outputs. Push-buttons on the 6 PNET inputs.
ADP-LX4
4 shades. Push-buttons on the 6 PNET inputs.
AQL-GV-RL4
4 on/off outputs.
AQL-GV-PMW3 / PMW4
3 or 4 dimmable outputs.
AQL-GV-010V4
4 dimmable 0-10 V outputs. Push-buttons on the PNET input.
GreenPlug
32 on/off outputs (1 to 32) and 8 dimmable (33 to 40). Push-buttons on the 28 PNET inputs.
QuickLight
4 dimmable outputs, 2 on/off and 12 buttons, in two 6-button keypads (buttons 1-6 and 7-12).
Keypad KP-1 / KP-2 / KP-3 / KP-5 / KP-6
Keypad with 1, 2, 3, 5 or 6 buttons, with LEDs. Inputs 1 and 2 when used.
Roehn 4 / Roehn 8
Roehn keypad with 4 or 8 buttons, in the module button order.
RGB
One color light (channels 1, 2 and 3 = red, green and blue).
Each connection name starts with the name given at registration, for example "Living Output 3" or "Shades Shade 2". The created drivers get the same name.
Each thermostat becomes a Universal HVAC Indoor Unit with the Off, Cool, Heat and Fan modes, Low, Medium and High fan, and a 16 to 30 °C setpoint. Modes and range can be adjusted in the Universal HVAC properties.
Push-buttons and inputs
Push-buttons wired to the PNET inputs of the modules join by themselves on the first press (with Auto Add Push-Buttons = Yes): the gateway creates a Universal Keypad Dry Contact "<name> PNET n" and one contact connection per button ("<name> PNET n Button k"), connected to the button input. The panel gains buttons as each one is used for the first time (up to 6). Press each button once before programming.
Click, double click, hold and the Button Links are on the Universal Keypad Dry Contact, with its own timing settings.
The dry-contact inputs of the keypads become contact connections ("<name> Input 1" and "Input 2") the first time they change state.
Keypad and QuickLight buttons support click, double and triple click and hold, with Button Links on the Universal Keypad. The LEDs follow the device connected to the Button Link.
Coming from version 1
V2 is a new driver and does not convert a V1 project. V1 (Smarthub and one driver per module) remains available for existing installations.
The V1 license (Smarthub) is valid for V2 on the same controller.
Do not use both versions at the same time on the same Smarthub.
Properties
Property
Description
License Key
License key provided by ZOOM.
License Status
License status (trial, active or invalid) and new version notice.
Control4 MAC Address
Controller MAC, used to register the license.
Driver Name / Driver Version
Name and version of the installed driver.
Driver Information
Last driver message (connection, registration, warnings).
Log Level / Log Mode
Log detail level and destination. The log returns to Off by itself.
ZOOMDH Debug
Debug password used by ZOOM support.
IP Address
Smarthub IP on the local network.
Connection Status
Status of the connection to the Smarthub.
Command Delay Milliseconds
Interval between commands sent to the Smarthub (100 to 1000 ms, default 250). Increase it if large scenes leave a load without responding.
Discovery Mode
Automatic (default): registers the modules and thermostats found on the network by itself. Manual: only through the Add Module and Add Thermostat actions.
Registered Devices
Registration summary: modules (how many automatic), lights, shades, keypads, push-buttons, thermostats and inputs.
Unregistered Modules
Module IDs seen on the ACNET network that are not registered yet.
Auto Create Devices
Yes: creates and connects the universal drivers on registration. No: only creates the connections.
Auto Add Push-Buttons
Yes: creates the PNET push-button panel (and its Keypad Dry) on the first press.
Actions
Action
Description
Discover Modules
Looks for the modules on the network again (with Discovery Mode = Automatic).
Add Module
Registers a module by hand (model, Module ID and name). Prevails over automatic registration. Registering the same Module ID again renames it; with another model, the outputs that remain keep their connections.
Remove Module
Removes the module and its connections (the universal drivers stay in the project, disconnected).
Add Thermostat / Remove Thermostat
Registers or removes a thermostat.
Create Missing Devices
Creates the universal drivers that are not yet connected to the gateway.
Refresh All States
Asks the Smarthub for the state of every module.
Show Devices
Lists the registration and connections in the Lua tab.
Send Command (diagnostics)
Sends a line to the Smarthub. Only works with ZOOMDH Debug active (support).
Connections
Connection
Connect to
<name> Output n, <name> (RGB)
ZOOM – Universal Light V2 (Light connection)
<name> Shade n
ZOOM – Universal Blind (Blind connection)
<name>, Buttons 1-6 / 7-12
ZOOM – Universal Keypad Bus (Keypad Gateway connection)
<name> PNET n Button k
ZOOM – Universal Keypad Dry Contact (Button k input)
<thermostat name>
ZOOM – Universal HVAC Indoor Unit (Indoor unit connection)
<name> Input n
Any driver that uses a contact (CONTACT_SENSOR)
Troubleshooting
Symptom
What to do
"No connection to the Smarthub"
Check the IP in IP Address, the network cable and whether the Smarthub responds on the local network.
The universal drivers were not created
Check that the universal drivers are installed on the Composer computer and use Create Missing Devices.
A module was not found
Use Discover Modules. If it is still missing, register it with Add Module. Addresses in Unregistered Modules are on the network but not registered.
Wrong model from discovery
Use Add Module with the right model and the same Module ID.
Push-button panel without buttons in Control4
Press each button once. Check Auto Add Push-Buttons.
Nothing responds
Check License Status.
Load state out of date
Use Refresh All States.
Licensing
The driver has a 30-day trial. After that a license is required, covering the gateway and every registered module. The V1 license (Smarthub) is also valid.
The ZOOM universal drivers are free.
The status is shown in License Status. The controller needs internet access to activate the license.
Operation
Valid license / trial
No license
Discovery, module registration and driver creation
First V2 release: a single driver for the Smarthub that finds the modules and thermostats by itself (or manual registration) and creates the ZOOM universal drivers already connected. Push-buttons join on the first press, on the Universal Keypad Dry Contact. The V1 license is valid on V2.