ZOOM – Absolute Controls Gateway v20261125

Driver: Control4 DriverWorks Platform: Absolute Smarthub gateway (ACNET network) Minimum OS: 3.0

PT EN

Overview

Version 2 of the Absolute Controls integration. A single driver talks to the Absolute Smarthub gateway over the local network and hands each module channel to the ZOOM universal drivers, the same ones used with Lutron, Home Manager IP and other systems:

The gateway finds the modules on the ACNET network by itself and creates the universal drivers already connected. You can also register each module by hand. The license lives only on the gateway.

Prerequisites

Installation

  1. Add the ZOOM – Absolute Controls Gateway driver to the project in Composer Pro.
  2. Enter the Smarthub IP in IP Address and check Connection Status.
  3. Enter the key in License Key (30-day trial).
  4. With Discovery Mode = Automatic (default), the gateway asks the Smarthub for the state of everything when it connects and registers the modules and thermostats that answer. Check the result in Registered Devices and with the Show Devices action.
  5. Fix or complete what is needed with Add Module (model, Module ID and name) and Add Thermostat (Thermostat ID and, if there is one, the Thermopad ID, temperature sensor). Manual registration always prevails over automatic.
  6. With Auto Create Devices = Yes, the gateway creates the universal drivers in its own room, already connected. Then just move each one to its room and rename it if you want.
With Auto Create Devices = No, add the universal drivers by hand and connect each one to the gateway connection with the same name (Connections tab). The Create Missing Devices action creates only the ones that do not exist yet.

Automatic discovery

Models and what each one creates

Model (Add Module)Connections created
ADP-DIM88 dimmable outputs. Push-buttons on the 6 PNET inputs.
ADP-RL1212 on/off outputs. Push-buttons on the 6 PNET inputs.
ADP-LX44 shades. Push-buttons on the 6 PNET inputs.
AQL-GV-RL44 on/off outputs.
AQL-GV-PMW3 / PMW43 or 4 dimmable outputs.
AQL-GV-010V44 dimmable 0-10 V outputs. Push-buttons on the PNET input.
GreenPlug32 on/off outputs (1 to 32) and 8 dimmable (33 to 40). Push-buttons on the 28 PNET inputs.
QuickLight4 dimmable outputs, 2 on/off and 12 buttons, in two 6-button keypads (buttons 1-6 and 7-12).
Keypad KP-1 / KP-2 / KP-3 / KP-5 / KP-6Keypad with 1, 2, 3, 5 or 6 buttons, with LEDs. Inputs 1 and 2 when used.
Roehn 4 / Roehn 8Roehn keypad with 4 or 8 buttons, in the module button order.
RGBOne color light (channels 1, 2 and 3 = red, green and blue).

Each connection name starts with the name given at registration, for example "Living Output 3" or "Shades Shade 2". The created drivers get the same name.

Each thermostat becomes a Universal HVAC Indoor Unit with the Off, Cool, Heat and Fan modes, Low, Medium and High fan, and a 16 to 30 °C setpoint. Modes and range can be adjusted in the Universal HVAC properties.

Push-buttons and inputs

Coming from version 1

Properties

PropertyDescription
License KeyLicense key provided by ZOOM.
License StatusLicense status (trial, active or invalid) and new version notice.
Control4 MAC AddressController MAC, used to register the license.
Driver Name / Driver VersionName and version of the installed driver.
Driver InformationLast driver message (connection, registration, warnings).
Log Level / Log ModeLog detail level and destination. The log returns to Off by itself.
ZOOMDH DebugDebug password used by ZOOM support.
IP AddressSmarthub IP on the local network.
Connection StatusStatus of the connection to the Smarthub.
Command Delay MillisecondsInterval between commands sent to the Smarthub (100 to 1000 ms, default 250). Increase it if large scenes leave a load without responding.
Discovery ModeAutomatic (default): registers the modules and thermostats found on the network by itself. Manual: only through the Add Module and Add Thermostat actions.
Registered DevicesRegistration summary: modules (how many automatic), lights, shades, keypads, push-buttons, thermostats and inputs.
Unregistered ModulesModule IDs seen on the ACNET network that are not registered yet.
Auto Create DevicesYes: creates and connects the universal drivers on registration. No: only creates the connections.
Auto Add Push-ButtonsYes: creates the PNET push-button panel (and its Keypad Dry) on the first press.

Actions

ActionDescription
Discover ModulesLooks for the modules on the network again (with Discovery Mode = Automatic).
Add ModuleRegisters a module by hand (model, Module ID and name). Prevails over automatic registration. Registering the same Module ID again renames it; with another model, the outputs that remain keep their connections.
Remove ModuleRemoves the module and its connections (the universal drivers stay in the project, disconnected).
Add Thermostat / Remove ThermostatRegisters or removes a thermostat.
Create Missing DevicesCreates the universal drivers that are not yet connected to the gateway.
Refresh All StatesAsks the Smarthub for the state of every module.
Show DevicesLists the registration and connections in the Lua tab.
Send Command (diagnostics)Sends a line to the Smarthub. Only works with ZOOMDH Debug active (support).

Connections

ConnectionConnect to
<name> Output n, <name> (RGB)ZOOM – Universal Light V2 (Light connection)
<name> Shade nZOOM – Universal Blind (Blind connection)
<name>, Buttons 1-6 / 7-12ZOOM – Universal Keypad Bus (Keypad Gateway connection)
<name> PNET n Button kZOOM – Universal Keypad Dry Contact (Button k input)
<thermostat name>ZOOM – Universal HVAC Indoor Unit (Indoor unit connection)
<name> Input nAny driver that uses a contact (CONTACT_SENSOR)

Troubleshooting

SymptomWhat to do
"No connection to the Smarthub"Check the IP in IP Address, the network cable and whether the Smarthub responds on the local network.
The universal drivers were not createdCheck that the universal drivers are installed on the Composer computer and use Create Missing Devices.
A module was not foundUse Discover Modules. If it is still missing, register it with Add Module. Addresses in Unregistered Modules are on the network but not registered.
Wrong model from discoveryUse Add Module with the right model and the same Module ID.
Push-button panel without buttons in Control4Press each button once. Check Auto Add Push-Buttons.
Nothing respondsCheck License Status.
Load state out of dateUse Refresh All States.

Licensing

OperationValid license / trialNo license
Discovery, module registration and driver creationOKOK
Commands to the modulesOKBlocked
State, button and thermostat feedbackOKBlocked

Support and Updates

Release Notes

VersionDateDescription
2026112511/25/2026First V2 release: a single driver for the Smarthub that finds the modules and thermostats by itself (or manual registration) and creates the ZOOM universal drivers already connected. Push-buttons join on the first press, on the Universal Keypad Dry Contact. The V1 license is valid on V2.