Platform driver for Crestron Home that controls the ControlArt MD-ETH wired modules over the local network (TCP 4998): MCRL1 / MCRL2 (relay, 12 inputs and 10 outputs) and MCDM1 (dimmer, 12 inputs and 9 outputs), plus the curtains driven by the module itself.
Each module has a page with status, firmware, curtain count and the mode of its 12 inputs.
Each output becomes a light in Crestron Home: on/off on the MCRL, dimmer on the MCDM1.
Each configured curtain channel becomes a shade with position, open, stop and close.
Inputs raise events for Crestron Home sequences (click / hold for push buttons, closed / open for switches).
Requirements
Crestron Home 4-Series processor with SDK V2 driver support.
MD-ETH modules on the processor network with a fixed IP or DHCP reservation.
TCP port 4998 open between the processor and the modules.
Installation
Copy ZoomDH_ControlArt_Modulos_Cabeados.pkg to user/ThirdPartyDrivers/Import on the processor (SFTP, port 22).
In Crestron Home Setup: Pair Devices > Drivers, choose ControlArt MD-ETH.
Fill in the setup (below) and finish. The modules show up as child devices to place in rooms.
Configuration
Field
Description
UI Language / Idioma
Portuguese or English.
Module IP Addresses
Module IPs separated by commas. Optional port: 192.168.0.50:4998.
License Key
ZOOM key. Empty = trial period.
The model (MCRL or MCDM) and the output count are read from the module on the first connection; the lights show up right after. Removing an IP from the list removes the module and its devices.
Module page
Status: connection, model, firmware and how many inputs are active. Refresh asks for MAC, firmware and status again.
Curtains (channels): number of curtains on the module (0 to 8). Curtain 1 uses module channel 0, Curtain 2 channel 1, and so on (same channel as the Blind Channel property of the Control4 driver).
Inputs: mode of each input. Push button (default) raises Click and Hold; Switch / sensor raises Closed and Open. The label shows the last event.
Commands and events (sequences)
Light: On, Off, Toggle, Set Level, Set Level With Ramp (dimmer, ramp in seconds), Pulse (on, then off after the time in ms).
Shade: Open, Close, Stop, Toggle, Set Position.
Module: Refresh Module; events Input N Click / Hold or Input N Closed / Open.
Driver: Check License.
Troubleshooting
Module "Not connected": check IP, cabling and that port 4998 answers. The driver retries every 5 to 60 s.
Lights missing: they are created after the first module status; tap Refresh on the module page.
Commands do nothing and the status says "commands blocked": invalid license or expired trial. Output status is still shown.
Logs: SSH to the processor, err / log; messages in Portuguese.
Licensing
ZOOM license per processor or per instance (product 202671). Without a key the driver runs in trial mode. Without a valid license no command is sent to the modules; connection and status keep working. The license status is shown on the driver page.
Initial Crestron Home release, port of the Control4 ControlArt IP Relay Module, IP Dimmer Module and IP Blind drivers: MCRL1/MCRL2 and MCDM1 modules over IP, outputs as lights, curtains per channel, mode and events of the 12 inputs, ZOOM license (DRIVER_ID 202671).