Platform driver for Crestron Home that integrates the Home Manager IP modules (X8, R12, E28 and the RF curtains of the IR+RF PRO) directly over the local network, without a Smart Center. It does the job of the Control4 Device Manager and X8 / R12 / E28 drivers.
In this version: IP modules X8, R12 and E28 and the RF curtains of the IR+RF PRO. The IR outputs of the IR PRO and IR+RF PRO are used by the ZoomDH IR air conditioner driver. Zigbee-only modules (R2, X1, X2, X4, Home One…), RGBW and the Yale lock come in later versions.
ZoomDH_HomeManager_IP.pkg to the processor (SFTP to /user/ThirdPartyDrivers/Import) or import it with Crestron Home Setup.Updating: each new package has a newDriverVersion(formatYYYYMMDDNN), so just import it over the old one. Modules and settings are kept on the processor. When updating from a version older than 2026112301, the existing Zigbee network becomes Network A with the same number and coordinator, without setting up the modules again.
| Field | Description |
|---|---|
| UI Language / Idioma | Portuguese or English: language of the driver pages. |
| Add New Modules Automatically | Yes (default): modules found on the network join the system and the default Zigbee network. No: only the modules already added are kept (use it after installation so modules of another job on the same network are not picked up). |
| Default Zigbee Network | Network new modules join: A (default), B, C, D or None to leave new modules out of any network. The first module of a network becomes its coordinator. |
| Module IP Addresses (optional) | Only if automatic discovery does not work: module IPs separated by commas. The model is detected from the module version. |
| Dimmer Ramp (X8) | Ramp of the X8 dimmers when the level is changed from Crestron Home: Instantaneo (instant), MuitoRapido (very fast, default), Rapido (fast), Medio (medium), Lento (slow), MuitoLento (very slow). |
| License Key | ZoomDH license key. Empty = 30-day trial. |
If Crestron Home Setup shows the options as a text box, type the value: the driver accepts any case and Portuguese words too (for example Network B, None, Yes, very fast).
On start and when you tap Search, the driver sends a broadcast and the modules answer with model, identification and Zigbee network. Modules also announce themselves when they power up.
The driver page shows, for each network, its number, coordinator and how many modules it has. NO COORDINATOR means a coordinator must be chosen. Rejoin members (second tap within 10 s) makes the IP modules of the network join again, one every 20 s. Zigbee-only modules and locks must be paired again on the device itself.
If a module IP changes, the driver recognizes the module by its identification and updates the IP on its own. Every day at 6:00 the driver asks all connected modules for their status.
| Module | Outputs | Inputs | In Crestron Home |
|---|---|---|---|
| X8 | 8 dimmers | 12 | 8 dimmer lights (0–100%) or up to 4 curtains, status of the 2 fuses |
| R12 | 12 relays | 16 | 12 on/off lights or up to 6 curtains |
| E28 | — | 28 | Input module: events of the 28 inputs and analog sensor |
Names follow the pattern "X8-1123456 - Output 3" (module model and serial number). Dimmer slider moves are grouped (250 ms) into one command. Changes made by the module inputs show up in Crestron Home right away.
Everything is on a single page, top to bottom:
| Item | Description |
|---|---|
| Status | Online/offline and IP, model, firmware, Zigbee network and role (or setting up), fuses (X8) and analog sensor reading. |
| Zigbee network / Zigbee role | Network A to D or None, and Coordinator or Member. See Discovery and Zigbee networks. |
| Curtains on outputs | For each output pair (1 and 2, 3 and 4…): Two lights or Curtain. See Curtains on outputs. |
| Analog input | Disabled, Temperature (LM35), Temperature (NTC) or Light level. With temperature, the offset from −10 to +10 °C is shown. |
| Input types | For each input: Push button, Switch, Sensor or Disabled. Written to the module right away. |
| Output power-up state | What each output does when the module powers up: Last state, On or Off. |
| Inputs toggle outputs (offline) | Writes the default action to the module: input 1 toggles output 1, input 2 output 2, and so on up to 8. Works without the Crestron processor and without the network. |
| Erase input actions | Erases the actions stored in the module (asks for a second tap within 10 s). |
| Rewrite configuration | Sends the input types, analog input and output power-up state again. The configuration is also written on its own when a new or replaced module connects. |
| Replace module | To replace a faulty module: tap, power off the old module and power on the new one (same model). The new one takes over the lights, curtains, settings, Zigbee network and role of the old one. It also works for the coordinator: the new one creates the same network and the members join again. Tap again to cancel. |
| Reboot | Reboots the module. |
| Remove module / Remove and release Zigbee | Removes the module and its devices from the system (second tap within 10 s). Release Zigbee also takes the module out of the Zigbee network. Removing a coordinator leaves its network without a coordinator until another one is chosen. |
The driver page (Home Manager IP) shows the module summary, automatic discovery, the Search button, the four Zigbee networks and the License.
On the X8 (up to 4 curtains) and R12 (up to 6), a pair of consecutive outputs can drive a curtain motor: the first output opens and the second closes, interlocked by the module itself.
The position is estimated from the travel time: an intermediate position is reached by moving the curtain and sending Stop at the computed time. At 0% or 100% the relays are released 5 s after the end of the travel. When the curtain is driven by a keypad stored in the module, Crestron Home follows the movement through the relay feedback.
The IR+RF PRO is found like the other modules. On its page, tap New RF curtain → Add to create each curtain; it shows up as a shade in Crestron Home. On the curtain page, under RF setup:
RF motors do not report their position: the driver estimates it from the travel time. An intermediate position is reached by moving the curtain and sending Stop at the computed time. If the curtain is moved with the original remote, the state in Crestron Home does not change.
| Device | Programmable commands | Events |
|---|---|---|
| Home Manager IP (driver) | Search Modules, Check License | — |
| Light (output) | On, Off, Toggle, Set Level, Set Level With Ramp (level + seconds), Pulse (milliseconds) | — |
| Curtain (outputs or RF) | Open, Close, Stop, Toggle, Set Position | — |
| Module | Write Default Input Actions, Reboot Module | Push button: Input N Click / Input N Hold. Switch and sensor: Input N Closed / Input N Open. |
The events of each input change with the type chosen on the module page.
When Module "X8-1123456" → "Input 3 Click"
Do Scene "Dinner"
| Symptom | Likely cause / fix |
|---|---|
| No module found | Modules on another network/VLAN or UDP 39090 broadcast blocked. Enter the IPs in Module IP Addresses. |
| Automatic discovery unavailable | The processor could not open UDP port 39090. Enter the module IPs in the configuration. |
| Module stays Offline | IP changed without automatic discovery, TCP port 29090 blocked or module powered off. The driver retries every 5 to 60 s. |
| New module does not join | Add New Modules Automatically is set to No. |
| Module status stays setting up | The module has not confirmed the Zigbee network yet. Check that it is powered and on the network; after 3 attempts the driver connects anyway and shows did not confirm Network X. Choose the network again on the module page. |
| Network shows NO COORDINATOR | The coordinator was removed or moved to another network. Set Zigbee role to Coordinator on a module of the network. |
| Fuse open on the X8 | Check the fuse shown on the module. |
| commands blocked (license) | Trial expired or invalid license. Enter the key in License Key. |
| Driver does not load on the processor | Check the processor log over SSH with the err command. |
The driver log (Crestron Home Setup or err over SSH) records discovery, Zigbee network, connections, commands and errors, in Portuguese.
| Operation | Trial active / licensed | Trial expired |
|---|---|---|
| Connection to the modules already added | OK | OK |
| Feedback of outputs, inputs and sensor | OK | OK |
| Output commands | OK | Blocked |
| Search, Zigbee network and module configuration | OK | Blocked |
Actions stored in the modules keep working without a license, because they run on the module itself.
| Version | Date | Description |
|---|---|---|
| 2026112301 | 2026-11-23 | Update with the improvements of the Control4 Home Manager IP package: up to four Zigbee networks (A to D), with the network and role chosen on each module page and coordinator change; curtains on two outputs of the X8 and R12; daily check at 6:00. The E28 is now an input-only module. Module page on a single page. |