Integrates Paradox EVOHD and Digiplex alarm panels with Control4 through the PRT3 module, over RS-232 serial.
Check that the user, zone and area names are correct in the PRT3: the driver downloads these names from the panel.
In the panel properties, the Zones screen lists the zones. Double-click a zone to open its options:
| Option | Description |
|---|---|
| Zone Name | Zone name in the driver. |
| Zone Type | Type of the sensor wired to the zone. The default is contact sensor. |
| Can Control | Always leave it off. |
| Hide from UI screens | Hides the zone on the zones screen of the interfaces. Show the zones in use and hide the others. |
| Chimes | Makes the Control4 screens chime when the zone opens. |
In each partition's properties:
| Option | Description |
|---|---|
| Allow Remote Disarming | Allows disarming from outside the local network. Unchecked, phones and tablets outside the Control4 network cannot disarm the system. |
| Default User Code | Code the driver uses to arm and disarm from programming. Create a user on the panel just for Control4. |
| Property | Description |
|---|---|
| License Key | Driver license key. Without a key, the driver runs in trial mode for 30 days. |
| License Status | License state (trial, active or invalid). |
| Control4 MAC Address | Controller MAC, used to register the license. |
| Driver Name / Driver Version | Installed driver name and version. |
| Driver Information | Last driver message (partition state, zones, errors). |
| Log Level / Log Mode | Log detail level and destination (Lua tab). Logging turns itself off after 45 minutes. |
| Connection Status | Shows whether the serial connection is bound. |
| Driver Actions | List of driver commands; see Actions. |
| Number of Partitions | Partitions in use on the panel, 1 to 8 (default 1). |
| Number of Zones | Panel zones, 0 to 192 (default 0). |
| Partition - Settings | Picks the partition edited by the next four properties. |
| Partition - ZonesInPartition | Zones of the partition, as a list or range (e.g. 1-8,12). The default is all zones. |
| Partition - Label | Partition name (default Area 1, Area 2...). |
| Partition - ExitDelay | Exit delay, 1 to 300 seconds (default 60). |
| Partition - EntryDelay | Entry delay, 1 to 300 seconds (default 30). |
| Users in System | Number of users, 1 to 255 (default 8). After changing it, use Download User Labels to bring the names. |
| User Settings / Edit User | Picks a user and edits their name in the driver. The name does not have to match the panel. |
| Service Email | Dealer e-mail: receives the warning when communication with the panel is lost. |
| Customer Email | Customer e-mail: receives arms, disarms, alarms and troubles. Separate several addresses with commas. |
| Customer Subject | Subject of the e-mails sent to the customer. |
| Last Email Sent | Last e-mail sent. |
| Send Push Notifications | Turns push notifications on or off. |
| Alarm Action: Flash_Lights | Lights that flash every 2 seconds during an alarm, until disarm or for 5 minutes. |
| Notify C4 GUI | Control4 screens that chime when the alarm goes off. |
Choose the command in the Driver Actions property.
| Action | Description |
|---|---|
| Check Connection | Requests the state of partition 1. Use it to test RS-232 communication with the panel. |
| Download Partition Labels | Downloads the area names from the PRT3. |
| Download Zone Labels | Downloads the zone names from the PRT3. |
| Download User Labels | Downloads the user names from the PRT3. |
| Command | Description |
|---|---|
| ARM_PARTITION_WITH_CODE | Arms a partition in Away, Force or Stay mode with the given user code. |
| DISARM_PARTITION_WITH_CODE | Disarms a partition with the given user code. |
| UTILITY_KEY | Triggers a panel utility key (1 to 251). |
| VIRTUAL_INPUT | Opens or closes a virtual input (1 to 16). |
| SMOKE_RESET | Resets the smoke detectors of an area (1 to 8). |
| PRESS_KEY | Sends a key to the panel. |
| ADV_CMD | Sends a free ASCII command to the PRT3. |
On the interfaces, each partition also offers the functions Arm all Partitions, Disarm all Partitions, Fire Utility Key, Check Status, Check Zone Status and Clear Troubles.
LAST_USER_EVENT, LAST_USER_NAME, LAST_USER_NUMBER, UTILITY_KEY_RECEIVED, LAST_PGM and ZONE_IN_ALARM.| ID | Connection | Use |
|---|---|---|
| 1 | Serial RS-232 | Controller serial port wired to the PRT3. |
| 5001 | Security Panel | Security panel, with the zones. |
| 5002–5009 | Security Partition 1–8 | Panel partitions (areas). |
| 7002–7009 | Room Selection Partition 1–8 | Rooms where each partition is shown. |
| 901–916 | Utility Key 1–16 | Relays that trigger utility keys 1 to 16. |
| Without a valid license | Behavior |
|---|---|
| Commands to the panel | Blocked: arm, disarm, status requests, utility keys and name downloads. |
| Messages from the panel | Ignored: partition and zone state, events and notifications. |
| Version | Date | Description |
|---|---|---|
| 20261012 | 2026-10-12 | Licensing library update. |
| 301 | 2024-05-13 | Added zone status check on the checkin timer. |
| 300 | 2023-11-06 | Updated licensing control code. |
| 205 | 2021-05-05 | Added the ZONE_IN_ALARM variable. |
| 204 | 2021-01-19 | Workaround for a Control4 bug that at some point stopped adding new zones to the panel. |
| 203 | 2021-01-04 | Added commands to arm and disarm partitions with a specific user code. The "Default User Code" property was removed from the main panel and is now set on each partition. |
| 202 | 2020-07-09 | Fixed the handling of the security system "TROUBLE" condition. |
| 201 | 2020-05-25 | Fixed partitions losing their zones after a controller restart. |
| 200 | 2020-04-22 | Fixed a bug in zone labels and notifications. |
| 100 | 2020-03-19 | Initial revision. |