ZoomDH – Paradox EVO RS232 v20261012

Driver: Control4 DriverWorks Platform: Control4 Minimum OS: 2.9.1

PT EN

Overview

Integrates Paradox EVOHD and Digiplex alarm panels with Control4 through the PRT3 module, over RS-232 serial.

Requirements

Panel setup

From the keypad

  1. Press and hold 0 and enter the installer code.
  2. Enter 953 (DGP-848) or 4003 (EVO 96/192) and fill in the requested data to reach the PRT3.
  3. In section programming, enter section 016 and leave only options 1, 3 and 4 on. Confirm with Enter.
  4. Press Clear until you leave programming.

From Babyware

  1. Right-click the PRT3 module and open Properties > Options tab.
  2. Enable [016]/1 (serial port) and [016]/4 (home automation protocol).
  3. Set [016]/2/3 to 19200 and [016]/5/6 to the ASCII protocol.
  4. Save the settings.

Check that the user, zone and area names are correct in the PRT3: the driver downloads these names from the panel.

Control4 installation

  1. Add the driver to the project and enter the key in License Key (the driver has a 30-day trial).
  2. Set Number of Zones and Number of Partitions.
  3. In Partition - Settings, pick each partition and set its name, zones and entry and exit delays.
  4. Set Users in System.
  5. For e-mail notifications, fill in Service Email and Customer Email.
  6. In Connections, bind the Serial RS-232 connection to the controller port. The driver starts querying the panel.
  7. In Driver Actions, use Download Partition Labels, Download Zone Labels and Download User Labels. With many zones or users, the download takes a while.
  8. Set the type of each zone (see Zones and partitions).
  9. Add a sensor for each zone and bind it to the matching panel input, to program per zone.

Zones and partitions

In the panel properties, the Zones screen lists the zones. Double-click a zone to open its options:

OptionDescription
Zone NameZone name in the driver.
Zone TypeType of the sensor wired to the zone. The default is contact sensor.
Can ControlAlways leave it off.
Hide from UI screensHides the zone on the zones screen of the interfaces. Show the zones in use and hide the others.
ChimesMakes the Control4 screens chime when the zone opens.

In each partition's properties:

OptionDescription
Allow Remote DisarmingAllows disarming from outside the local network. Unchecked, phones and tablets outside the Control4 network cannot disarm the system.
Default User CodeCode the driver uses to arm and disarm from programming. Create a user on the panel just for Control4.

Properties

PropertyDescription
License KeyDriver license key. Without a key, the driver runs in trial mode for 30 days.
License StatusLicense state (trial, active or invalid).
Control4 MAC AddressController MAC, used to register the license.
Driver Name / Driver VersionInstalled driver name and version.
Driver InformationLast driver message (partition state, zones, errors).
Log Level / Log ModeLog detail level and destination (Lua tab). Logging turns itself off after 45 minutes.
Connection StatusShows whether the serial connection is bound.
Driver ActionsList of driver commands; see Actions.
Number of PartitionsPartitions in use on the panel, 1 to 8 (default 1).
Number of ZonesPanel zones, 0 to 192 (default 0).
Partition - SettingsPicks the partition edited by the next four properties.
Partition - ZonesInPartitionZones of the partition, as a list or range (e.g. 1-8,12). The default is all zones.
Partition - LabelPartition name (default Area 1, Area 2...).
Partition - ExitDelayExit delay, 1 to 300 seconds (default 60).
Partition - EntryDelayEntry delay, 1 to 300 seconds (default 30).
Users in SystemNumber of users, 1 to 255 (default 8). After changing it, use Download User Labels to bring the names.
User Settings / Edit UserPicks a user and edits their name in the driver. The name does not have to match the panel.
Service EmailDealer e-mail: receives the warning when communication with the panel is lost.
Customer EmailCustomer e-mail: receives arms, disarms, alarms and troubles. Separate several addresses with commas.
Customer SubjectSubject of the e-mails sent to the customer.
Last Email SentLast e-mail sent.
Send Push NotificationsTurns push notifications on or off.
Alarm Action: Flash_LightsLights that flash every 2 seconds during an alarm, until disarm or for 5 minutes.
Notify C4 GUIControl4 screens that chime when the alarm goes off.

Actions

Choose the command in the Driver Actions property.

ActionDescription
Check ConnectionRequests the state of partition 1. Use it to test RS-232 communication with the panel.
Download Partition LabelsDownloads the area names from the PRT3.
Download Zone LabelsDownloads the zone names from the PRT3.
Download User LabelsDownloads the user names from the PRT3.

Commands

CommandDescription
ARM_PARTITION_WITH_CODEArms a partition in Away, Force or Stay mode with the given user code.
DISARM_PARTITION_WITH_CODEDisarms a partition with the given user code.
UTILITY_KEYTriggers a panel utility key (1 to 251).
VIRTUAL_INPUTOpens or closes a virtual input (1 to 16).
SMOKE_RESETResets the smoke detectors of an area (1 to 8).
PRESS_KEYSends a key to the panel.
ADV_CMDSends a free ASCII command to the PRT3.

On the interfaces, each partition also offers the functions Arm all Partitions, Disarm all Partitions, Fire Utility Key, Check Status, Check Zone Status and Clear Troubles.

Events and variables

Connections

IDConnectionUse
1Serial RS-232Controller serial port wired to the PRT3.
5001Security PanelSecurity panel, with the zones.
5002–5009Security Partition 1–8Panel partitions (areas).
7002–7009Room Selection Partition 1–8Rooms where each partition is shown.
901–916Utility Key 1–16Relays that trigger utility keys 1 to 16.

Troubleshooting

Licensing

Without a valid licenseBehavior
Commands to the panelBlocked: arm, disarm, status requests, utility keys and name downloads.
Messages from the panelIgnored: partition and zone state, events and notifications.

Support and Updates

Release Notes

VersionDateDescription
202610122026-10-12Licensing library update.
3012024-05-13Added zone status check on the checkin timer.
3002023-11-06Updated licensing control code.
2052021-05-05Added the ZONE_IN_ALARM variable.
2042021-01-19Workaround for a Control4 bug that at some point stopped adding new zones to the panel.
2032021-01-04Added commands to arm and disarm partitions with a specific user code. The "Default User Code" property was removed from the main panel and is now set on each partition.
2022020-07-09Fixed the handling of the security system "TROUBLE" condition.
2012020-05-25Fixed partitions losing their zones after a controller restart.
2002020-04-22Fixed a bug in zone labels and notifications.
1002020-03-19Initial revision.