ZoomDH – Universal Virtual Thermostat IR v20261111

Driver: Control4 DriverWorks Platform: IR-controlled air conditioners Connection: Controller IR output

PT EN

Overview

Virtual thermostat driver for Control4, to control air conditioners by IR. The driver queries an online database for the list of compatible devices: whenever a model is updated or added, it becomes available for selection.

Prerequisites

Installation

  1. Add the driver to the project in Composer Pro and bind the IR Emitter connection to the IR output in use.
  2. Enter the key in License Key.
  3. Choose the search method in Select Search Method: air conditioner brand and model, or remote control model.
  4. Select the brand in Device Brand and the model in Device Model, or the remote in Remote Model. Use Request Thermostat List to refresh the list from the server. The driver configures itself.
  5. Check the chosen device in Device Selected and test the commands.

Custom commands

The driver accepts additional IR commands, which show in the Extras tab of the interfaces. Choose the action in Custom Commands:

ActionDescription
Add New IR commandAdds a command: enter the name in Command Name and paste the hex IR code in Command IR Code.
Edit a IR commandEdits a command: select it in Command List and paste the new code in Command IR Code.
Delete a IR commandDeletes the command selected in Command List.
Show Commands in the LUA tabLists the commands in the Lua tab.
Export Extra CommandsSaves the custom commands so they can be imported into other instances of the driver.
Import Extra CommandsImports the commands saved by another instance of the driver.

Properties

PropertyDescription
License KeyDriver license key.
License StatusLicense status and update information.
Control4 MAC AddressController MAC, used for licensing.
Driver Name / Driver VersionName and version of the installed driver.
Log LevelLog detail level (0=Alert … 5=Trace).
Log ModeLog destination: Off / Print / Log / Print and Log.
Driver InformationDriver status messages.
Thermostat TypeControl type. Currently IR only.
IR Repeat CountNumber of times the IR code is sent. Default: 1.
Select Search MethodDatabase search method: air conditioner brand and model, or remote control model.
Device BrandDevice brand. Request Thermostat List refreshes the list from the server.
Device ModelDevice model, listed after the brand is chosen.
Remote ModelRemote control model, when searching by remote.
Remote ImageURL with the picture of the selected remote control, when the database has one.
Device SelectedDevice selected for control.
Send Power On FirstYes: sends a power on command before the first mode command when the unit is off. Default: No.
HVAC Modes / Fan ModesOperation modes and fan speeds available for the selected device.
Hide Heating ModeYes: hides heating mode from the interfaces. Default: No.
Cool Min / Max and Heat Min / MaxCooling and heating setpoint limits.
Room Temperature CRoom temperature used by the thermostat.
Custom CommandsManages the custom IR commands (see the section above).

Connections

ConnectionUse
IR EmitterIR output that controls the air conditioner.
SlaveLink to the ZoomDH – Universal Thermostat Controller driver, to control several thermostats at once.
Temperature InInput for a temperature sensor.
On Button LinkTurns the thermostat on in the last mode and temperature used, with no programming.
Off Button LinkTurns the thermostat off.
Toggle Button LinkToggles the thermostat state (on/off).

Troubleshooting

Licensing

What the license controls

OperationTrial activeTrial expired
Brand and model selection from the databaseOKBlocked
IR commands to the air conditionerOKBlocked

Support and Updates

Release Notes

VersionDateDescription
2026111111/11/2026The driver now reports the installation's technical data to the license server once a day, which speeds up support. It also shows in License Status when a new driver version is available.
2026102810/28/2026Model list and IR codes are now released only to a licensed driver or one in its trial period. Models without discrete on and off commands: the normalizing command is now always sent before turning on and off, including installations where the model was already selected.
2026101410/14/2026Thermostat list and IR codes loaded from the new site address (zoomdigitalhome.com.br), fixing the empty brand and model lists. The files are now served only to the driver.
2026101212/10/2026Licensing library update.
2026082828/08/2026Workaround for models without discrete on/off commands.
2026070707/07/2026Minor fixes.
31611/03/2026Made the Send Power On First command compatible with the SWING ON / SWING OFF version.
31519/08/2025Fixed an error in the decimal number conversion function.
31417/07/2025Fixed the conversion of temperatures using "," instead of "." as the decimal separator.
31316/07/2025Added support for the SWING ON and SWING OFF modes, in the Extras tab.
31222/05/2025Added support for fan speeds in dehumidify mode.
31112/03/2023Added support for fan speeds with a space in the name.
31015/07/2024Adjusted the Preset Changed event call.
30924/05/2024Added support for the multiple thermostat control driver.
30822/05/2024Added support for custom commands.
30721/05/2024Fixed the Send Power On First command.
30601/02/2024Added support for presets and schedules.
30505/12/2023Fixed an error in a temperature scale parameter variable.
30423/06/2023Fixed an error in the setpoint up and down commands.
30312/06/2023Adjusted the fan mode code.
30207/03/2023Added fan mode and the property to hide heating mode from the interfaces.
30122/06/2022Added device search by remote control model.
30020/06/2022Initial release.